Perkins — Perkins 4.108 4.107 4.99 Diesel Engine Workshop Manual

ELECTRICAL EQUIPMENT -Q.3 Low-Unsteady Charging Rate If reading obtained is stable but outside the appropriate limits the unit can be adjusted as follows. (a) Check driving belt for correct tension and wear. (b) Check for high resistance at battery terminals Stop the engine and remove the control unit from its mounting. At the back of the unit is a sealed potentio- meter adjuster. Carefully scrape away the sealing com- pound. Then start the engine, and while running the alternator at charging speed, turn the adjuster slot - CLOCKWISE to INCREASE the setting or ANTI- CLOCKWISE to DECREASE it - until the required set- ting is obtained.

ADJUSTMENT OF VOLTAGE SETTING and in the circuit wiring and connection. (c) Check all connections made to earth. (d) Apply Test 2. Flat Battery or Low State 01 Charge (a) CHECK condition of battery with hydrometer and high rate discharge tester. Recheck the setting by stopping the engine, then start again and slowly "run-up" to charging speed. If set- ting is now correct, remount the control unit, dis- connect test meters and restore original wiring con- nections. If, after adjustment, the voltmeter reading re- mains unchanged, or increases in an uncontrolled manner, then the control unit is faulty and a replace- ment must be fitted. (b) Check driving belt for correct tension and wear.

(c) Check that the field isolating relay contacts open when master switch is off, otherwise battery will discharge through rotor winding. (d) Check that flat or low battery is not caused by electrical loads by applying Test 4. insufficient alternator output caused by abnormal TEST 4 Excessive Charge Rate to a Fully Charged Battery (a) Apply Test 3. Check Alternator Output Disconnect battery earth cable, and connect test ammeter between the alternator main terminal and disconnected cables. Reconnect battery earth cable, and switch on the vehicles full electrical load and leave on for 3 or 4 minutes. Leave load on and start engine and run at approximately 2000 rev/min.

The alternator output should balance the load, and at the same time show a charge to the battery. Noisy Alternator (a) Alternator loose in mounting brackets. (b) Worn frayed or loose drive belt. (c) Worn bearings, fully out of alignment. (d) Rotor damage or pulley fan loose on shaft. Check Warning Ught Control (e) Open circuited, or short circuited rectified diodes, or stator winding open-circuit. If warning light does not function either by remaining "on" or "off", but the system is charging satisfactorily, connect voltmeter between the alternator "AL" terminal and earth. Reading should be 7.0-7.5 max (12 volt alternator) or 14.0-15.0 (24 volt alternator).

Con- nect leads 'E' and 'WL' together. If warning lamp lights the warning light control is faulty and should be re- placed. (f) Loose pulley. 6. Testing the 15ACR and 17ACR Alternator in Position The nominal hot outputs at 6,000 rev/min (alternator First check the driving belt for condition and tension. speed) are 28 amps and 36 amps for 15ACR and 17 ACR alternator respectively. These figures may be 5. faun Diagnosis Procedure for 11 AC exceeded slightly when the alternator is running cold. Alternator Fails to Charge cedure should therefore be carried out with the alter- To avoid misleading results, the following test pro- (a) Check driving belt for correct tension and wear.

(b) Apply Tests 1 and 2. nator running as near as possible to its normal opera- ting temperature.