ELECTRICAL EQUIPMENT -Q.S LUBRICATOR IN COMMUTATOR END BRACKET 2. Routine Maintenance (a) Lubrication Every 4,000 miles (6,000 km) or 150 running hours, inject a few drops of high quality S.A.E.30 engine oil into the hole marked "OIL" at the commutator end bearing housing (Refer to Fig. Q.2). (b) Inspection of Brushgear Every 72,000 miles (108,000 km) or 2,700 running hours, the dynamo should be removed from the engine and the bushgear inspected by a competent electrician. ( C) Belt Adjustment FELT RING RETAIN ER INJECT _-----\_..:::..:. OIL HERE Every 4.000 miles (6.000 km) or 150 running hours. in- spect the dynamo driving belt, and if necessary.
adjust to take up anv slackness by turning the dynamo on its mounting. Care should be taken to avoid overtightening the belt (see Page M.1). FELT RING POROUS BRONZE BUSH 02 3. Performance Data The cutting in and maximum output speeds quoted below are production test figures and refer to cold machines with brushes only partly bedded. Model C40-1. Cutting-in Speed. 1450 rev/min (Max.) at 13.0 dynamo volts. Maximum Output. 22 amp at 2250 rev/min (Max.) at 13.5 dynamo volts and a resistance load of 0.61 ohms. Field Restistance. 6.0 ohms. 4. Start the engine and set to run at normal idling speed. 5.
Clip the negative lead of a moving coil type volt- meter, (calibrated 0-20 volts) to one dynamo ter- minal and the positive lead to a good earthing point on the yoke. 6. Gradually increase the engine speed, when the voltmeter reading should rise rapidly and without fluctuation. Do not allow the volt meter reading to reach 20 volts, and do not race the engine in an attempt to increase the voltage. It is sufficient to run the dynamo up to a speed of 1,000 rev/min. If the voltage does not rise rapidly and without fluctuation the unit must be dismantled for internal examination. Excessive sparking at the commutator in the above test indicates a defective armature which should be replaced. NOTE:
If a radio suppression capacitor is fitted between the output terminal and earth, disconnect this capacitor and re-test the dynamo before dismantling. If a reading is now given on the voltmeter, then the capacitor is defective and must be replaced. If the dynamo is in good order, 4. Servicing Testing in Position 1. Inspect the driving belt and adjust if necessary. (Refer to Page M.1). 2. Check the connection on the commutator end bracket. The larger connector carries the main dynamo output, the smaller connector the field current. 3. Switch off all lights and accessories, take off the cables from the terminals of the dynamo and con- nect the two terminals with a short length of wire.
MODEL C40~1 GENERATOR. DISMANTLED POROUS BRONZE BUSH flSRE THRUST WASHER YOKE SHAFT COLLAR CUP FELT RING SHAn KEY SHAFT NlfT OUTPUT 'TERM I ""'L 'D' BOLTS RETAINING PLATE. ORIVE END BRACKET PULLEY SPACER 03