ELECTRICAL EQUIPMENT -0.8 STARTER MOTOR-PRE·ENGAGED DRIVE (See Fig. 0.7) 4. Check bearings for excessive side play of arma- ture shaft. 5. Check pinion movement. 6. Clean and lubricate the indented bearing inside the pinion sleeve using a bentonite based grease for this purpose. 7. Clean and lubricate the indented bronze bearing in the intermediate bracket. Use Ragosine 'Molypad' Molybdenised non-creep oil for this purpose. 1. Description-Model M45G or 2M113 with Model 7S Solenoid. This starter motor is a four-pole, four-brush earth re- turn machine with series-parallel connected field coils. A solenoid-operated pre-engaged drive assembly is carried on an extension of the armature shaft.
The main feature;" of this type of drive are as follows: (a) Positive pinion engagement preventi,ng the pinion being thrown out of mesh whilst starting. (b) Dual-purpose plate clutch incorporated in the drive assembly giving over-speed and over-load protec- tion. (c) Self-indexing pinion to ensure smooth engagement between the pinion and the flywheel teeth before the starter motor begins to rotate. (d) Armature braking system to ensure rapid return to rest when the starter button is released. 3. Servicing (a) Testing in Position Switch on the lamps. If the vehicle is not equipped with lighting, then connect a 0-20 voltmeter across the battery terminals before proceeding.
Operate the starter control and watch for the following symptoms:- The lamps dim or voltmeter rearling drops to about 6 volts. and the motor does not crank the engine. Check battery (must be at least half-charged) and battery lugs, (clean and a good earth connection). Check by hand that engine turns freely. 2. Routine Maintenance (a) The starter motor requires no routine maintenance beyond the occasional inspection of the electrical connection which must be clean and tight, the brush gear, and the commutator. (b) After the starter motor has been in service for some time, remove the starter motor from the engine and submit it to a thorough bench inspec- tion. 1.
Brush wear (this is a fair indication of the amount of work done). Renew brushes worn to, or ap- proaching, 5/16 in (7,9 mm) in length. 2. Brush spring tension. Correct tension is 30 - 40 ozf (0,85-1,13 kgf). Renew springs if tension has dropper below 25 ozf (0,71 kgf). 3. Skim commutator if it is pitted or badly worn. 2. The lamps do not dim, the voltmeter reading re- mains steady at about 12 volts, and the motor does not crank the engine. Connect voltmeter from solenoid terminal 'BAT', and starter yoke, operate starter:- No volts indicated (a) Poor lug connections at battery. (c) Broken starter lead, battery to starter. (b) Bad earth connection. Full volts i.e., 12-14 volts indicated.
(a) Faulty solenoid switch. (b) Open circuit in starter-check brushes. COPPE.R SOLENO 10 LI~ UNIT ~b ENGAGEMENT LEvER ECCENTR Ie PIVOT PIN BEARING BUSH DRIvE EN'O BRACKET ~~~~Ґ~~~~~=iiiiiiiiiilINTER.MEOIATE BRACKET ~ BEARING BUSH : \ I RETAiN!NG RING COMMUTATOR END BRACKET Q7 ARMATURE