MAN — MAN DD13 DD15 Engine Application Installation Manual

DD PLATFORM APPLICATION AND INSTALLATION MANUAL 8.7.9 MINIMUM COOLANT TEMPERATURE The overall design should ensure minimum coolant temperature 71°C (160°F) be maintained under all ambient operating conditions; operating conditions are listed on www.detroitdiesel.com.. A cold running engine can result in poor engine performance, excessive white smoke, and reduced engine life. 8.7.10 SYSTEM PRESSURIZATION DD Platform engines typically require a minimum 62 kPa (9 psi) pressure cap. See www.detroitdiesel.com for specific requirements. The pressure caps raise the boiling point of the coolant which minimizes coolant or flow rate loss due to localized boiling and water pump cavitation.

Higher rated pressure caps may be required for high altitude and severe ambient operation. Cooling system components must be able to withstand increased pressure. 8.7.11 COOLANTS A proper glycol (ethylene, propylene) or extended life organic acid, water, Supplemental Coolant Additive (SCA) mixture meeting DDC requirements is required for year-round usage. The coolant provides freeze and boil protection and reduces corrosion, sludge formation, and cavitation erosion. Antifreeze concentration should not exceed 67% for ethylene glycol (50% for propylene glycol). Detroit Diesel requires SCAs be added to all cooling systems at initial fill and be maintained at the proper concentration.

Follow SCA manufacturers' recommendations. Refer to Coolant Selections for Engine Cooling Systems (DDC-SVC-BRO-0002), available on www.detroitdiesel.com. 8.8 CHARGE AIR COOLING REQUIREMENTS Sufficient cooling capability is required for optimum engine performance. Exceeding the system temperature and pressure design limits defined in this chapter can adversely affect fuel economy, power, emissions and durability. 8.8.1 COOLING CAPABILITY The cooling capability of the air-to-air system must be sufficient to reduce the turbocharger compressor out air temperature to within 25°C (45°F) of ambient temperature on all DD Platform engines.

Air inlet manifold temperature requirements are available on www.detroitdiesel.com. Typically the maximum intake manifold temperature is 85°C (185°F). 8.8.2 MAXIMUM PRESSURE LOSS The maximum allowable total static pressure drop across the DD Platform charge air system is 13.5 kPa (4 in. Hg). This includes the restriction of the charge air cooler and all the plumbing and accessories (e.g. shutdown valve) from the turbocharger compressor to the engine air inlet manifold. All information subject to change without notice. 8-17 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION