DD PLATFORM APPLICATION AND INSTALLATION MANUAL Beaded pipe ends must be used to prevent the hose from separating from the pipe. Fittings on the lines (especially fill line) must not reduce effective size. Quality constant tension hose clamps must be used to maintain tension and prevent leakage during both cold and hot operation. Use the correct style of clamp when silicone hoses are used. Two clamps should be used at each connection, indexed 180° apart. Figure 8-15 Hose Clamp 180° Indexed Position Connections must be flexible enough to accommodate relative motion between connecting components.
Quality hoses that can withstand the expected temperatures, pressures, coolants, and inhibitors must be used. Corrugated hoses are not recommended. Hoses must be fuel and oil resistant. Hoses should not span more than a 2 in. (5 cm) unsupported section. Use reinforced hose for longer spans. All connecting hoses and pipes must provide adequate support to prevent collapse and rupture. Loose internal springs are not recommended. All lines must have a continuous downward slope without droops to ensure good cooling system draining and refilling capabilities. Additional drains and vents may be required if this is not possible. All information subject to change without notice.
8-23 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION