MAN — MAN DD13 DD15 Engine Application Installation Manual

COOLING SYSTEM, AIR-TO-AIR CHARGE COOLING 8.11.2 COOLING AIR FLOW RESTRICTION Core selection and location must meet charge air system temperature and pressure drop limits, and must be compatible for good coolant radiator performance. Charge air coolers have a cooling air flow restriction typically between 0.19 and .37 kPa (0.75 and 1.5 in. H 2 O). 8.11.3 MATERIAL Most charge air coolers are made of aluminum alloys because of their light weight, cost advantages and good heat transfer characteristics. Other materials may be used with approval from DDC Applications Engineering.

8.11.4 HEADER TANKS Header tanks should be designed for minimum pressure loss and uniform airflow distribution across the core. Rounded corners and smooth interior surfaces provide a smooth transition of the air flow resulting in minimum pressure loss. The inlet and outlet diameters of the header tanks should be the same as the pipework to and from the engine. A 5 in. (127 mm) minimum diameter is required for the DD Platform engines. The tube ends require a 0.09 in. (2.3 mm) minimum bead to retain hose and clamp connections. 8.11.5 LOCATION The cooler is typically mounted directly in front (upstream of air flow) or along side the engine coolant radiator.

Other locations are acceptable as long as performance requirements are met. The cooler should be located as close to the engine as practical to minimize pipe length and pressure losses. Leave access space between the cores when stacked in front of one another so debris may be removed. 8.11.6 PIPEWORK Give careful attention to the pipework and associated fittings used in the inlet system, in order to minimize restriction and maintain reliable sealing. Pipework length should be as short as possible in order to minimize the restriction incurred in the system and to keep the number of bends to a minimum.

Use smooth bend elbows with an R/D (bend radius to tube diameter) ratio of at least 2.0 and preferably 4.0. The cross-sectional area of all pipework to and from the charge air cooler must not be less than that of the intake manifold inlet. The recommended tube diameter for DD Platform engines is 5 in. (127 mm) for both the turbocharger to CAC heat exchanger, and from the CAC heat exchanger to the engine air intake manifold. 8-26 All information subject to change without notice. DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION