DD PLATFORM APPLICATION AND INSTALLATION MANUAL Water pump inlet restriction must be kept to a minimum to prevent cavitation. This means radiators, auxiliary oil coolers located between the radiator and the pump inlet (not preferred location), as well as the associated plumbing must introduce minimal restriction. Lines connected to the water pump inlet must have at least the same area as the pump inlet. Bends should be kept to a minimum and they should have a generous radius (no mitered bends). The water pump inlet pressure (suction) must not exceed allowable limits (see the Information Highway for actual limits).
The lowest pressure in the entire cooling system is found at the water pump inlet. This pressure can be below atmospheric; thus cavitation (boiling) will occur below 100°C (212°F) at sea level. Altitude causes higher probability of cavitation in cooling systems. The pump can easily become air bound if a large volume of air is trapped in the pump during coolant filling, or if air is fed to the pump when the pump is running. Vehicle heater systems can be a major source of air. Air can also be introduced into the cooling system from a severely agitated or improperly designed top tank. Alternatively, an optional water pump group with an inlet elbow is available.
It provides a traditional inlet position and it includes vent and fill line ports. 8.11 CHARGE AIR COOLING DESIGN GUIDELINES The air to air CAC system should be designed for the highest horsepower engine offered in the application. The same system can be used for derated versions of the engine, which offers the following advantages: Reduces the number of components in the manufacturing and part systems Lower power engines may achieve even greater fuel economy from the additional reduction in engine intake air temperature Extends engine life The following guidelines will assist in the design and selection of the various components that make up the charge air system.
It is critical that these components offer maximum air temperature reduction with minimal loss of pressure. The integrity of the components must provide for long life in its operating environment. Air system operating parameters such as heat rejection, engine air flow, air pressure, maximum pressure drop, and minimum temperature loss are available on www.detroitdiesel.com. Charge air cooler considerations include size, cooling air flow restriction, material specifications, header tanks, location, and fan systems. 8.11.1 SIZE The size of the heat exchanger depends on performance requirements, cooling air flow available, and usable frontal area.
Using the largest possible frontal area usually results in the most efficient core with the least amount of system pressure drop. Consult your supplier to determine the proper heat exchanger for your application. All information subject to change without notice. 8-25 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION