MAN — MAN DD13 DD15 Engine Application Installation Manual

DD PLATFORM APPLICATION AND INSTALLATION MANUAL NOTICE: The fan should never operate in the stall area, where a small change in static pressure results in no change in airflow. NOTICE: The air side of the cooling system is critical and a change in the air flow will generally have a greater impact on cooling than a similar percentage change in coolant flow. Consider these additional factors to determine actual fan performance at worst case operating conditions. Air temperature Atmospheric pressure PERSONAL INJURY To avoid injury from rotating belts and fans, do not remove and discard safety guards. Fan curves are generated at standard conditions (77°F [25°C] 0 elevation).

If the fan is operating in different temperature or pressure (altitude) than standard the performance must be adjusted. 8.13.1.2 Fan Position Fan position relative to the radiator depends on the fan diameter and the radiator frontal area. Position the fan further away from the core as the fan swept area becomes less than the radiator frontal area. This allows the air to spread over the full core area. The fan will not spread air over the entire core area if it is mounted too close to the radiator. The optimum position of the fan blade on a blower or suction fan with respect to the shroud opening is dependent on the fan design as well as the many variables associated with an installation.

Different system performance may occur for the same fan positions in different applications due to air flow restriction and flow obstructions. Consult the fan manufacturer for assistance in optimizing the fan positioning. Keep fan tip-to-shroud clearance to a minimum because it influences air flow and noise level significantly. Minimum clearance is achieved by using a shroud with a round opening. An adjustable fan shroud is recommended if the fan pulley is adjustable for belt tightening. Consider allowances for engine/radiator movement when determining tip clearance. Consider components located behind the fan so air flow is not adversely affected or vibration introduced to the fan.

These conditions will cause premature failures, or increased noise, or both. Fan height is also important. All information subject to change without notice. 8-33 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION