COOLING SYSTEM, AIR-TO-AIR CHARGE COOLING Figure 8-18 Typical Fan Performance Curve Most fans have some region in which the flow separates from the blade and the flow becomes unstable. This is called a stall region. Operation in the stall region is not recommended because results are not consistent and the fan is inefficient and noisy. There are maximum tip speeds in the range of 18,000 to 23,000 feet per minute that the fan manufacturer based on his design. Check with the fan manufacturer. The system characteristics are defined by the air flow restrictions that are a result of:

Engine enclosure louvers Engine and accessories Fan guard Radiator core Charge air cooler if in tandem with radiator Oil cooler if in tandem with radiator Bug screen Any other internal or external obstructions 8-32 All information subject to change without notice. DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION