DD PLATFORM APPLICATION AND INSTALLATION MANUAL Increasing core thickness increases the restriction to air flow. This condition causes fouling to occur faster. Consider the following when analyzing fan performance: Speed Static Pressure Horsepower The following fan law relationships are useful when interpreting basic fan curves: Air flow varies directly with fan speed ft. 3 /min. 2 = (ft. 3 /min. 1 ) x (r/min. 2 ) / (r/min. 1 ) Static head varies with the square of fan speed P S2 = (P S1 ) x [(r/min. 2 ) / (r/min. 1 )] 2 Horsepower varies with the cube of fan speed hp 2 = (hp 1 ) x [(r/min. 2 ) / (r/min.
1 )] 3 Additional factors that affect the installed performance of a fan are listed in the following table. Table 8-2 Installed Fan Performance Factors Typical fan performance graphs have total pressure curves and power absorption curves for a given speed of rotation. The pressure, measured in water gage, represents the resistance to flow. The higher the resistance, the lower the flow. The fan horsepower absorption follows a similar, but not exactly the same, characteristic to the pressure curve. Depending on the installed system characteristics, the fan operates only at one point of water gage and power. All information subject to change without notice.
8-31 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION Installed Fan Factors Affecting Performance Fan Position Fan to Core Distance, Fan to Engine Distance Air Flow Restriction Radiator Core, Engine and Engine Compartment Configuration, Grills and Bumpers, Air Conditioning Condenser, Air-to- Oil Cooler, Air-to-Air Cores Shroud Shroud-to-Fan Tip Clearance, Shroud-to-Fan Position, Shroud Type (i.e. Ring, Box, Venturi), Shroud-to-Core Seal, Shutters, Bug Screens, and Winterfronts