MAN — MAN DD13 DD15 Engine Application Installation Manual

COOLING SYSTEM, AIR-TO-AIR CHARGE COOLING 8.14 RADIATOR COMPONENT DESIGN The design of individual radiator components may have an effect on cooling system performance. The following sections describe these considerations. 8.14.1 DOWN FLOW AND CROSS FLOW RADIATORS Down flow radiators are customarily used and required for heavy duty diesel engine applications. A cross flow radiator may be used if height limitations exist, but deaeration, thermal stratification, adequate core tube coverage and freeze damage are generally more difficult to control.

Figure 8-20 Down Flow Radiator and Cross Flow Radiator 8.14.1.1 Horizontal Radiator Horizontal radiators may be used in situations where space restrictions preclude the use of other types. It is essential that vent lines go to the fill tank with the cap. Consult DDC Application Engineering for assistance in applying horizontal radiators. 8.14.1.2 Rapid Warm-up Deaeration Tank — Down Flow Radiator The rapid warm-up deaeration tank consists of an integral top tank or a remote tank with the same design features. The top tank design should provide the following characteristics:

A non turbulent chamber for separating air (gases) from the coolant Ability to fill at a minimum specified rate 8-36 All information subject to change without notice. DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION