DD PLATFORM APPLICATION AND INSTALLATION MANUAL Table 8-3 Top Tank Component Guidelines Standpipe(s), Baffle, Vortex Baffle, Fill Line and Connections, Vent Line, and Radiator Inlet All information subject to change without notice. 8-39 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION Component Guidelines Standpipe(s) Locate the standpipe(s) as far away from radiator inlet(s) as practical and center over core. This is the area of least coolant turbulence, thus best for separating air out of the coolant. Use 1 or 2 standpipes with 0.25 in. (6.35 mm) inside diameter (general rule). Bottom of tube must not protrude below baffle. Top of tube must extend above hot full coolant level.
The flow must be directed away from the low coolant level sensor, as well as the filler neck and/or pressure relief valve opening. This minimizes coolant loss. Baffle A clearance of 1 in. (25.4 mm) or more should be maintained between the top of the radiator core and the bottom of the top tank baffle. This produces a good transition of the coolant flow and enhances air separation from the coolant. Seal baffle completely so the only flow path between the deaeration tank and the radiator core is through the standpipe(s). This is essential for proper engine warm-up, preventing top tank coolant agitation, and providing a positive head on the water pump.
Vortex Baffle Use a vortex baffle to prevent formation of a coolant vortex. This also permits maximum usage of top tank coolant volume. A vertical baffle is preferred. Horizontal vortex baffles at the fill line opening may hinder the venting of trapped air. Fill Line and Connections The recommended minimum inside diameter is 1 in. (25.4 mm). Fill line connections (fittings) must not reduce the minimum inside diameter requirement. Locate the fill line as low as possible above the baffle and at the center of the tank. This minimizes uncovering the fill opening and drawing air into the cooling system during vehicle operations.
Make the engine connection as close to the water pump inlet as practical. This will provide maximum head to the water pump and minimize heat migration to the radiator core, resulting in quicker engine warm-up. Avoid connecting the fill line to the coolant bypass circuit. A continuous downward slope (including fittings) must be maintained from the top tank to the water pump inlet to ensure good filling capabilities. Vent (deaeration) Line – High Position (above coolant level) Radiator Inlet Locate the vent line at the top of the top tank above the coolant level in the deaeration space. The recommended line size is 3/16 in.
(4.76 mm) inside diameter Do not direct deaeration line coolant flow toward the fill neck, pressure relief valve openings, or low coolant level sensor All vent lines must maintain a continuous downward slope Locate the radiator inlet as low as possible with at least the lower half of the inlet below the baffle level to minimize air trapped during fill. The inside diameter of the inlet should match the inside diameter of the thermostat housing. Design the radiator inlet to uniformly spread coolant under the baffle. The radiator inlet must be sealed from top tank No vent holes.
Extend the fill neck into the tank to establish the cold coolant full level, allowing for expansion (6%) and deaeration (2%) volume.