MAN — MAN DD13 DD15 Engine Application Installation Manual

ELECTRICAL SYSTEM External or internal tooth lock washers are not recommended for battery cable electrical connections. Frame area where ground connection is made should be stripped of paint and tinned to prevent corrosion. Recommended battery cable connections to the frame have hardened steel flat washers with a locking nut. 11.2.5.2 Cable Loss Test Procedure Correct sizing and installation can be checked by measuring voltages. Once you have the voltages: Battery Voltage minus Motor Voltage equals Cable Loss. Measure voltages for correct sizing as follows: 1. Tighten nuts holding battery cables to solenoid and starter terminals. NOTE:

Solenoid “BAT” terminal is at battery voltage when batteries are connected. 2. Connect the positive carbon pile lead to the starter solenoid “BAT” terminal. Connect the negative lead to the starter ground terminal. 3. Connect the battery cables within the battery box and tighten to specification. 4. Adjust the load to 500 amps. 5. Quickly measure voltage of a connected battery (measure at a terminal nut or actual post). 6. Turn off load, allow carbon pile to cool. 7. Connect voltmeter to the solenoid “BAT” terminal and starter ground. Connect directly to terminals, not to load clamp. 8. Adjust load to 500 amps. 9. Measure motor voltage. 10. Turn off load.

11.2.5.3 Measuring Circuit Resistance To measure cranking circuit resistance, disconnect positive and negative cables at the battery. Install a galvanometer or precision ohmmeter (0.0001 ohms resolution) and read the resistance. Resistance should be less than the maximum allowable for this system. If the measurement exceeds the maximum values, corrective measures such as cleaning the connections, reducing the number of connections, or increasing wire gage will have to be taken. 11-12 All information subject to change without notice. DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION