DD PLATFORM APPLICATION AND INSTALLATION MANUAL 11.2.4 GROUNDING REQUIREMENTS The preferred method of ground return is to use a copper cable from the ground side of the cranking motor or alternator back to the battery. The cable size should be the same as the supply cable coming from the battery. When calculating the correct cable size, the distance from the battery to the cranking motor or alternator as well as the ground return distance must be used to determine the total cable resistance or system voltage drop. 11.2.5 WIRING Cables and wiring are an important part of the electrical system which is often overlooked or neglected.
The cables are the highway on which the electrical energy travels. Just one faulty or dirty connection can reduce electrical energy transfer just as surely as traffic on a modern four lane highway that is narrowed down to one lane. As long as traffic is light there is no problem but during rush hour it is quite different. Cranking the engine on a cold morning with a faulty or dirty connection which restricts the flow is the same as rush hour on a suddenly reduced highway. 11.2.5.1 Guidelines for Electrical Wiring Guidelines for electrical wiring start with determining the vehicle or chassis type, system voltage, starting motor type, batteries used, and location.
That information is then used to determine proper routing, cable length and size, insulation, terminals, routing clamps, loom or conduit requirements and connections. Use for following guidelines for electrical wiring: Rope stranded copper cable is recommended for #0 or larger cable sizes because of its added flexibility. A full copper circuit is recommended for all installations because it maintains the lowest resistance and is the most trouble free. Good cable routing is not too tight or loose, is properly supported, and avoids excessive heat, abrasion, and vibration. Conduit or loom should be considered to protect cable where extreme heat or abrasion cannot be avoided.
Die-cast lead alloy terminals are recommended for post-type batteries. Sealed terminals are recommended where sealed terminal batteries are available. Ring terminals are not recommended for battery connections but are recommended for other connections. Clamps should be used to support the battery cable every 24 in. and to relieve strain at battery and motor terminals, around corners, and other stress points. All information subject to change without notice. 11-11 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION