DD PLATFORM APPLICATION AND INSTALLATION MANUAL 4. Moments of inertia Ixx, Iyy, Izz about the CG if known. Otherwise, a dimensional drawing of the engine is needed to make an estimate. 5. Mounting pad positions x, y, and z relative to RFOB and crankshaft centerline. 6. Desired amount of isolation if known, usually a minimum of 90%, and 96-98% for generators in buildings. 7. Any expected shock or impact loads described in g's and direction. 8. Closest point x, y, z and clearances to machine members. 9. Any external forces, such as belt and chain drives, their direction and position. 10. Any environmental conditions such as temperature highs and lows, chemical or oil exposures, etc.
For common, non shock load applications the general procedure for self selection of mounts has two possible methods: Method A: Select a type of mount that supports the load from the supplier catalog and then calculate its isolation capability. Method B: Specify the isolation desired and calculate the mount characteristics required to obtain this. Then select the mount from the catalog. For more details and formulas to use in your calculations, refer to Barry Controls bulletin IOEM1, or Lord Manufacturing bulletin PC2201o. The suitability of the selected mounts should still be confirmed with the manufacturer.
Detroit Diesel assumes no responsibility for the resilient mounting system performance. 12.3.1.1 Method A Select a type of mount that supports the load from the supplier catalog. 1. Determine the location of CG of the engine and transmission package. 2. Calculate the reaction forces at each mount using the weight and CG. Some mount manufacturers include safety factors up to three times the mount load rating, to allow for forces due to engine torque and rugged terrain, so weight only is normally sufficient to use for this calculation. However, if the power package will be subject to low gear, high torque operation, then the force due to torque must be added.
Consult the manufacturer to be sure. 3. Refer to the mount tables in the catalog that suits the application and the environmental conditions. There might be more than one suitable table to refer to. 4. From your table of choice, select a mount that is within the load range. There might be several mount models to choose from. 5. Using constant for stiffness (K) from the table or accompanying load vs. deflection charts, and the weight (W) at the mounting point, calculate the natural frequency (Fn.) of that mount. All information subject to change without notice. 12-5 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION