DD PLATFORM APPLICATION AND INSTALLATION MANUAL 15.1.1.3 Air Starters Requiring Lubricators Where lubricators are required, proper starter lubrication is a must. Ensure that the lubricator gets a positive feed of fuel; without proper starter lubrication the engine cranking speed will be greatly reduced. The starter may need to be prelubed prior to installation. Contact the starter manufacturer for instructions. 15.2 AIR COMPRESSOR Detroit Diesel offers two sizes of air compressors on DD Platform engines: the single cylinder BA–921 rated at 16 cfm, and the twin cylinder BA–922 rated at 32 cfm. Both compressors are adaptorless style installations 1. Gear Case 3.
Single Cylinder Air Compressor 16 CFM 2. Twin Cylinder Air Compressor 32 CFM 4. Crankcase and Cylinder Block Figure 15-1 Single Cylinder Air Compressor 16 CFM and Twin Cylinder 32 CFM These air compressors are driven by the bull gear and are water-cooled. Engine coolant is fed to the compressor through a flexible hose tapped into the engine block water jacket or a line from the water pump, which is then connected to the front of the compressor. Coolant returns from the rear of the compressor through a flexible hose to the engine cylinder head. Lubricating oil is supplied to the compressor by a line from the cylinder block oil gallery that connects to the air compressor.
Lubricating oil returns to the engine crankcase through the air compressor drive assembly. Air compressors may require any or all of the following components for operation: Governor All information subject to change without notice. 15-3 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION