MAN — MAN DD13 DD15 Engine Application Installation Manual

COLD WEATHER STARTING AND STARTING AID SYSTEMS 16.2.2 DIESEL FUEL The diesel fuel used is very important for obtaining satisfactory engine performance, long engine life, and acceptable exhaust emissions. For EPA 2007 exhaust emission compliant engines, the use of Ultra-Low Sulfur Diesel (ULSD, 15ppm) is critical. When operating for prolonged periods of idling or in cold ambient conditions (below 0°C/32°F), the use of 1-D fuel is recommended. Please note, transit coach engines are emissions certified on both No. 1 and No. 2 fuel; to maintain emission compliance, use only certified fuel.

Please refer to the publication Lubricating Oil, Fuel and Filter Recommendations (DDC-SVC-BRO–0001) at detroitdiesel.com. DDC does not recommend the use of supplemental additives in the fuel for improving the fuel for cold temperature operation. If fuel heaters are used on electronically controlled engines, fuel temperature to the Motor Control Module (MCM) inlet cannot exceed 60°C (140°F) . Incomplete fuel combustion is indicated by appearance of white, gray, or bluish exhaust smoke. White or gray smoke is a sign of incomplete combustion in the cylinders and may be counteracted by increasing the fuel Cetane number.

Blue smoke is indicative of insufficient fuel vaporization and can be corrected by an increase of fuel volatility or by increasing the cylinder combustion temperature. 16.2.3 COOLANT An engine coolant solution of water and antifreeze must be used to protect the engine coolant system when operating in ambient conditions below freezing. Detroit Diesel Power Cool (P/N 23512138) is recommended to be mixed with water for a 50-50 solution. DD Power Cool is an ethylene glycol coolant, if a propylene glycol coolant is used, it must meet the requirement TMC RP-330 “Type A”.

Please refer to the Detroit Diesel Customer Support Network (DDCSN) on the internet for more information regarding our coolant recommendations. Refer to DDC publications Coolant Selections (DDC-SVC-BRO-0002) for engine coolant details. The most commonly used antifreeze solutions is ethylene glycol. A 25% solution protects to -12°C (+10°F), a 50% solution protects to -36°C (-33°F), and a 63% solution protects to -59°C (-75°F). However, note that a 100% solution freezes at -22°C (-8°F). (A solution containing more than 67% ethylene glycol is not recommended.) There is another inhibitor package used with ethylene glycol consisting of a Nitrite Organic Acid Technology (NOAT).

This does not affect the antifreeze performance; this also applies for NOAT antifreeze. The other common type of antifreeze is propylene glycol. See for freezing point of aqueous propylene glycol solutions. 16-4 All information subject to change without notice. DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION