DD PLATFORM APPLICATION AND INSTALLATION MANUAL Figure 16-2 General Battery Cranking Power - Percent 16.2.5 STARTER MOTOR Electric starter motors are recommended for use with Detroit Diesel engines. Other types of starter motors exist, but are not generally recommended. 16.2.5.1 Electric Starter Motor Correct motor size depends on the torque required to crank the engine and parasitic loads. To obtain dependable starting, the starting motor must be capable of turning the engine and parasitic loads. Cranking of the engine should not exceed 15 seconds or the starter and/or engine may be damaged. Cranking motor speed is directly proportional to the motor terminal voltage.

To obtain the highest motor terminal voltage, it is necessary to limit the cranking circuit resistance to less than .0008 ohms for this 12 volt systems. All information subject to change without notice. 16-7 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION