COLD WEATHER STARTING AND STARTING AID SYSTEMS The starting circuit design should be analyzed. The starting circuit includes the number and size of batteries, cables including size, length and connectors, the starter and any device the starter must rotate during cranking. This includes the engine and parasitic loads such as automatic transmission, power steering pump, hydraulic pump(s), fan(s) and alternator(s). The Original Equipment Manufacture must determine the lowest expected ambient temperature the vehicle or application is expected to start.
All the information should be reviewed with the starter manufacture for further analysis and recommendations of which starter motor is appropriate. Generally, as parasitic loads increase and the ambient temperature decrease the cranking load imposed on the starter motor increases causing a reduction in cranking speed. For more information on DDC compliant electric starter motors, please refer to “Electrical Systems” section of this manual. 16.3 COLD WEATHER STARTING There are many different external hardware, engine components and approaches used to achieve cold weather starting. This section contains these in the following topics:
Starting Systems Starting Aids Starting Procedures Engine Starting Requirements 16.3.1 STARTING SYSTEMS The following hardware systems are used to improve cold weather starting by reducing the negative affects of low ambient temperatures. These systems may affect the engine starting procedure. 16.3.1.1 Intake Air Heater An intake air heater, or grid heater, comes standard on DD Platform engines. The grid heater uses electric current to heat the air entering the intake manifold. The heated air temperature aids in cold weather starting by increasing the temperature of the combustion fluid to a temperature suitable for compression ignition.
16.3.1.2 Coolant Tank Type Heaters Tank type heaters consist of resistance type elements mounted inside of a tank. Coolant enters at one point of the tank and exits at a second point. Heated coolant rises to the top of the block and is replaced by unheated coolant. Some tank type heaters contain a valve at the entrance to the tank. This valve causes a "percolating" action and results in better circulation of coolant through the engine. The valve also serves as a check valve and prevents coolant flow through the heater during engine operation. 16-8 All information subject to change without notice. DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION