DD PLATFORM APPLICATION AND INSTALLATION MANUAL In order to obtain a rapid warm up of the coolant a separate coolant, a circulating pump should be included with the tank type coolant heater. It is important that the heater is not energized while the engine is running. The tank type heater requires two connections to the engine coolant system. The tank inlet connection must be taken from a point, which is low in the coolant system on the suction side of the pump. The exit side of the heater should be connected to a coolant point high in the engine cylinder block. It is important that the heater be installed inlet to pump suction to prevent a bypass coolant path during engine operation.
The tank type heater can be installed on any engine and can be designed with kW capacities large enough to preheat the coolant in any engine. Various thermostat ranges may be chosen so that the final temperature can be controlled as required. It should be noted that these temperature rise charts are based on laboratory data. However, the wattage requirements may vary slightly depending upon the location of the heating element relative to the cylinder walls, the configuration of the coolant passages, and the flow rate of coolant through the passages. The wattage requirements specified are without wind considerations.
This curve is based on a 12-hour heating time with 80% of the temperature rise occurring in the first five hours of heating. All information subject to change without notice. 16-9 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION