AUXILIARY POWER UNITS (APU) Figure 18-5 DD15 with 4-Port Coolant Return Manifold Coolant supply and return lines should be routed away from the turbocharger turbine housing and any exhaust components. Both lines should be routed forward of the turbocharger compressor discharge elbow and below the turbo inlet, down toward the frame rail. The lines should be securely fastened to the engine so as not to unnecessarily stress the fittings which may result in coolant leaks. Avoid sharp bends and angles whenever possible. A minimum spacing of 13mm is required between coolant lines and the frame rails. See photographic examples of coolant line routings in the last section of this chapter.

Figure 18-6 DD15 with 2-Port Coolant Return Manifold 18-8 All information subject to change without notice. DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION