MAN — MAN DD13 DD15 Engine Application Installation Manual

DD PLATFORM APPLICATION AND INSTALLATION MANUAL DD15 engine shown with 2-port coolant return manifold. For installations having a 2-port manifold, the rear coolant line (bunk heater return) should be used to return coolant from the APU. If a tee fitting is used, it should be installed into the rear port of the manifold. The bunk heater return is connected to the outboard port on the tee, and the APU coolant return is plumbed to the rear facing port on the tee. A “Y” connector could also be used to connect to APU return to the bunk heater return line. Refer to Detroit Diesel Coolant Selections Bulletin, 7SE298, for proper selection of engine coolant and additives.

If an APU is selected that shares engine coolant with the main vehicle engine and could also run simultaneously, an installation review would be required from Detroit Diesel Application Engineering prior to installation. 18.3.3 APU EXHAUST SYSTEM The APU exhaust system must remain separate from the main vehicle engine exhaust system. Under no circumstances should the APU exhaust be connected to the main vehicle exhaust piping. Care should be taken to route the APU exhaust away from the cab and all air intake locations.

18.3.4 APU ELECTRICAL SYSTEM If the APU requires input from the main vehicle engine electronics to indicate when the main vehicle engine is running, the ignition signal from the main vehicle engine is located in the CPC on pin #3 of connector #2. All information subject to change without notice. 18-9 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION