DD PLATFORM APPLICATION AND INSTALLATION MANUAL NOTICE: Do not mount the alternator and / or generator near exhaust components that radiate substantial heat. Mounting near substantial heat sources could overheat the alternator, generator and / or regulator. 18.4 APU ENGINE START-UP PROCEDURE It is important to verify the installation has been performed correctly and to prepare the various APU sub-systems for proper operation. The A/C circuit, the lubrication system, the cooling system, and the fuel system all must be in proper working condition before the APU is started for the first time to avoid unnecessary component damage.
DO NOT operate the APU engine before a partial refrigerant charge has been added or damage to the A/C compressor will result. NOTICE: BEFORE operating the APU engine check the oil level. Add the proper amount and type of oil, if needed. 18.4.1 BLEEDING THE COOLANT SYSTEM Bleed as follows: 1. Verify the APU OUTLET hand valve is CLOSED. If this valve is left open, coolant will be sitting on top of the TriPac thermostat and not allow the TriPac engine to bleed air. 2. Open the APU INLET hand valve. 3. Place a clean container under the bleed line to catch coolant that is drained. 4. Entrapped air must be purged from the main vehicle engine after filling the cooling system.
To do this, allow the engine to warm up with the pressure cap removed. With the transmission in neutral, increase engine speed to 1,000 rpm and add coolant to the surge tank as required. 5. Open the bleed petcock on the APU engine to allow air to bleed out. 6. When a steady stream of coolant flows from the bleed line, close the petcock. 7. Open the APU OUTLET hand valve. 8. Replace drained coolant from the TriPac back into the tractor’s radiator. 9. Bleed TriPac fuel system. Refer to section "Bleeding The Fuel Lines". All information subject to change without notice. 18-11 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION