AUXILIARY POWER UNITS (APU) Verify the APU engine has proper amount of oil and the A/C system has a partial refrigerant charge before starting the engine. 10. Start the TriPac engine. 11. The remaining air in the system will be forced to the tractor radiator and the TriPac APU should now be bled of all air. 18.4.2 BLEEDING THE FUEL LINES Bleed as follows: 1. Locate the On/OFF switch inside the APU and turn the switch “ON”. 2. Open the fuel return line banjo fitting on the APU engine. 3. At the HMI (in-cab APU control panel): [a] Press MAIN POWER Key “ON”. [b] Press APU SYSTEM Key “ON”. [c] Press MODE Key to “AC”. [d] Press FAN Key to set fan speed.
[e] Press UP or DOWN Keys to set the thermostat to 50°F (10°C). [f] Multiple start attempts will be required to start the engine. NOTE: The fuel pump only runs when the engine is turning over. If the engine cranks for 30 seconds and fails to start, a start fault shutdown will be generated. This alarm code will have to be cleared before attempting another start sequence. 4. Close the fuel return line banjo fitting when a steady flow of fuel is observed. 5. Allow engine to start. 18.4.3 VERIFYING ENGINE OPERATION Once the APU engine is running: Verify with a strobe light tachometer the engine rpm is 1800 RPM loaded (A/C clutch engaged). Adjust as required.
Check cooling system for leaks Check for fuel leaks 18-12 All information subject to change without notice. DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION