Service Manual for WD10 Diesel Engine Turn on the machine power switch and connect test lamp to generator B+ terminal and E (negative) terminal. It means there is no voltage in B+ terminal, Is the test lamp on? NO the wire to battery positive is in failure. YES Connect one end of test lamp to generator D+ terminal instead of E terminal. terminal is in failure NO Is the test lamp on? Circuit in generator D+ YES Start the engine Is the test lamp on? Generator failure YES NO Generator is fine Fig. 4-85 Generator fault diagnosis flow chart 124