Service Manual for WD10 Diesel Engine b) Low charging voltage 126 b. Check whether generator output end B+ to ground voltage is about 24V (battery voltage). a. If B+ terminal to ground voltage is zero, then check generator to battery positive and negative circuits for breakover. b. If B+ terminal to ground voltage is obviously lower than battery voltage, then check whether generator to battery positive and negative circuits are loose or the battery is damaged. Recommended detection method: Connect a 2W indicator lamp to generator B+ terminal and exciting D+/L terminal, observe working condition of the indicator. Troubleshooting:
The brightness of indicator lamp is normal, and it goes out automatically after engine is started, generator output voltage is 27~28.5V; it means the exciting circuit has problem and needs to be repaired. The brightness of indicator lamp is normal, but it doesn’t go out after engine is started, generator output voltage is 27~28.5V; it means generator regulator has problem and needs to be checked. The brightness of indicator lamp is normal, but it doesn’t go out after engine is started, generator output voltage is battery voltage; it means there is fault in generator regulator, rectifier bridge, stator or inner connectors, and needs to be repaired or replaced.