Weichai — Weichai WD10 Diesel Engine Service Manual

Service Manual for WD10 Diesel Engine 127 Fault 2: Low charging voltage Phenomenon Fault detection Troubleshooting Battery is occasionally underpowered, low charging voltage, and the voltage declines markedly once loaded. Check whether generator output power is reasonably matched with electrical appliances. a. Check whether voltmeter is damaged. b. Check generator speed. c. Check the quality and tensioning situation of generator belt and relevant pulley belts. d. Check generator pulley. e. Check whether electric wires are reasonably connected, measure the voltage of generator and battery. f.

Check whether wires in charging system are loose, oxidized and producing too much heat, check whether bolt connections are loose. g. Measure output voltage of generator W/R/AC terminal (should be about half of B+ terminal voltage). h. Check whether battery charging is normal. Measure generator B+ terminal voltage, which should be within 27.8~28.4V, if the voltage is normal, then it means voltmeter failure or voltmeter sampling point is in fault, repair or replace. a. It is recommended the generator idling speed should exceed 1600rpm. b. Generator speed should be 2000rpm and above, or the voltage should be about 27V when high power load appliance like air condition is working c.

Check the quality of generator belt and relevant pulley belts, for belt involved severe coking, breakage, deformation or wear should be replaced. Tension generator belt and relevant pulley belts. ATTENTION: If the to-be replaced belt is in twin-drive belt system, then the belts should be replaced together. d. Tension it if it is loose. e. If voltage drop is bigger than 1V in heavy load condition (thin wire results in big voltage drop), the wire should be replaced. 0~35A S≥6mm2 35~70A S≥12mm2 70~100A S≥20mm2 100~150A S≥25mm2 If the wire or connector gets too hot in heavy load condition, then the wire or connector should be replaced. f.

Oxidized lead foot and the housing that used to install grounding bolts should be polished before reassembling. Retighten the loose nuts and lug plates, re-plug the loose connectors firmly. ATTENTION: Reassembled or retightened parts should be run in heavy load and will be overheat, check whether the overheat is still there 3~5min later. g. If there is big difference between terminal W/R/AC output voltage and normal range and big voltage drop happened after the engine loaded, then it means failure in generator rectifier bridge or stator, repair or replace. h.

If charging current drops to about 10A 10min later, or charging current reaches to 30-90A for a long time, then the battery is damaged, repair or replace the battery.