CLAAS LEXION II (480 - 405) — gb 00 Deckblatt

TIC LEXION 480-405 SAUER hydrostatic drive Test instructions 1. - Connect a test gauge to both high-pressure sides 2. - Apply the parking brake 3. - Warm the system to a working temperature of approx. 60° 4. - Bring the hydrostatic lever to the neutral position 5. - Start the engine and run in normal speed 6. - Check that the charge pressure is at 30 ± 2.5 bar 7. - Check that the charge pressure difference on either side does not exceed max. 7 bar 8. - Completely swash the pump in one direction 9. - Pressure drop on the low-pressure side: max. 4 bar 10. - Switch the engine to idle 11. - Select third gear 12. - Operate the system brakes 13. - Swash the hydrostatic pump for a max.

of 5 sec slowly forwards 14. - Check the high pressure reading 420 to 450 bar 15. - Check the low pressure reading min. 14 bar 16. - Swash the hydrostatic pump for a max. of 5 sec slowly backwards 17. - Check the high pressure reading 420 to 450 bar 18. - Check the low pressure reading min. 14 bar 19. - Stop the engine 20. - Remove the test gauges 03/2004 7-35