CLAAS LEXION II (480 - 405) — gb 00 Deckblatt

SAUER hydrostatic drive LEXION 480-405 TIC 7.10 Maintenance Filling instructions 1. - Put the machine in third gear 2. - Switch on the four wheel drive 3. - Pull on the handbrake 4. - Connect a test gauge to both sides of the high-pressure lines (M1 and M2) 5. - Fill the tank with hydraulic oil 6. - Remove the relay for engine watch dog, or remove the wire loop 7. - Turn the engine over quickly with the starter motor. 8. - Check the oil level and correct 9. - Continue the procedure until one of the pressure sides reaches about 15 bar 10. - Reconnect the relay for the engine watch dog, or the wire loop 11. - Start the engine and run in idle 12. - Load the system for approx. 1 min.

to 50-150 bar in the forwards direction 13. - Load the system for approx. 1 min. to 50-150 bar in the reverse direction 14. - Stop the engine 15. - Check the oil level and if necessary top up 16. - Put the machine into neutral 17. - Start the engine and run in idle 18. - Swash the hydrostatic pump for approx. 2 min. in the forwards direction 19. - Swash the hydrostatic pump for approx. 2 min. in the reverse direction 20. - Stop the engine 21. - Check the oil level and if necessary top up 22. - Stand the steering axle up on suitable blocks 23. - Engage 4 wheel drive 24. - Start the engine and run in idle 25. - Swash the hydrostatic pump for approx. 2 min. in the forwards direction 26.

- Swash the hydrostatic pump for approx. 2 min. in the reverse direction 27. - Check that both turning wheels have a pressure of approx. 150 bar 28. - Stop the engine 29. - Check the oil level and if necessary top up 30. - Lower the steering axle 7-34 03/2004