Standard machine functions LEXION 480-405 TIC Basic settings To ensure that the spool (H) for the front end attachment is in the correct position, the distance between the top edge of the spool (H) and the housing, with the solenoid (Y85) removed should be 4.3 mm . The position can be corrected by inserting or removing shims from the top of the spring. Under the spool for the returns valve (U), there is a weaker pressure spring than that of the spool (H). The drop speed of the front end attachment can be adjusted on the flow control valve (614) and needs to be adjusted so that the total drop time is about 5-6 sec .
Operation of the returns valve The primary function of the returns valve (Y77) is to stop the flow of oil between the P and the T when a system requires it. The exception is when a component requires to be discharged to tank. In the neutral position, the returns valve (Y77) is not switched, and the oil flows across the ring channel of the spool (U) and back to tank. Because of the size of the channel, the back pressure is slight. Should there be the requirement of a component for pressure, the returns valve (Y77) will be switched at the same time as the component. The spool (U) closes the connection between P and T.
The connection is closed, firstly by closing the ring channel, so that a gentle switch over is achieved. Should the system pressure exceed 175 ± 15 bar, then the pressure relief valve (703) is opened and the excess is dumped to tank. 3-18 03/2004