CLAAS LEXION II (480 - 405) — gb 00 Deckblatt

Standard machine functions LEXION 480-405 TIC Operation of the front end attachment Slow lower When the function “slow lower” has been selected, then the solenoid (Y87) is switched with a pulse signal of 80Hz at approx. 45% PWM (Pulse width modulation) using the CAC module. The switching signal is sufficient to push the ball off the seat of the valve (V), but is not enough to press against the force of the spring (F). The spool (E) is therefore not in a position to close the ring channel for the return oil. The weight of the front end attachment forces oil over the ball seat, through the holes of the spool (E) and in the return line back to tank.

The reduced flow rate via the spool means that the front end attachment lowers at a slower rate. Operation of the front end attachment Fast lower With the function “fast lower”, the solenoid (Y87) is operated with the full 12 V DC. The ball is unseated from the control valve (V) and the spring force (F) is overcome with the force exerted by the solenoid valve. The spool (E) closes the return ring channel. The weight of the front end attachment forces the oil onto the surface area of (K). Due to the difference in surface areas, the valve (S) is then forced open. The oil then passes through valve (S), the control spool (R) and then back to tank.

The drop rate of the front end attachment is in this case mainly dependent on the flow control valve (614). 3-20 03/2004