Standard machine functions LEXION 480-405 TIC Operation of the front end attachment Slow lower When the function “slow lower” has been selected, then the solenoid (Y87) is switched with a pulse signal of 80Hz and approx. 37% PWM (Pulse width modulation) using the CAC module. The switching signal is sufficient to push the ball off the seat of the valve (V), but is not enough to close the seat of the valve tightly. The spool (E) is not then in a position to close the ring channel for the return oil. The weight of the front end attachment forces oil over the port (A1) and the ball seat via the pin seat into the return line back to tank.
The reduced flow rate via the spool means that the front end attachment lowers at a slower rate. Operation of the front end attachment Fast lower With the function “fast lower”, the solenoid (Y87) is operated with the full 12 V DC. The ball is unseated from the control valve (V) and the pin seat closed so that the weight of the front end attachment forces the oil onto the surface area of (K). Due to the difference in surface areas, the return valve (S) is then forced open. The oil then passes through return valve (S), the control spool (R) and then back to tank. The drop rate of the front end attachment, is then dependent on the flow control valve (614). 3-26 03/2004