19-64 19-64 Electrical System Troubleshooting Inspection 1: Inspect for continuity and short circuiting of the harness. Ignition key switch OFF, disconnect G27 and G18 Standard: Inspection 2: Carry out crank angle sensor individual inspection. Ignition key switch OFF, disconnect G27 and G18 1 2 Standard: (Sensor side) G18 Inspection 3: Carry out crank angle sensor installation inspection. Ignition key switch OFF, disconnect G27 and G18 Standard: Remove the crank angle sensor, ensure that there is no foreign matter etc. adhereing to the sensor part. If there is remove it. Section 19 G27-11 ~ G18-1 Continuity G27-22 ~ G18-2 Continuity G27-11 ~ G27-22 No continuity G18-1 ~ G18-2 1100 ± 150 Ω