OM4035.2 02/03 Maintenance - Section 4 Automatic Lube System Page 4- 19 GENERAL INSTRUCTIONS LUBRICANT REQUIRED FOR SYSTEM Pump Pressure Control Grease requirements will depend on ambient tempera- tures encountered during truck operation: High pressure hydraulic fluid from the truck steering system is reduced to 325 to 350 psi (2 240 to 2 413 kPa) by the pressure reducing valve located on the manifold on top of the pump motor. This pressure can be read on the gauge installed on the manifold and should be checked occasionally to verify pressure is within the above limits. •Above 90°F (32°C) - Use NLGI No.2 multipurpose grease (MPG). •-25° to 90°F (-32° to 32°C) - Use NLGI No.
1 multipur- pose grease (MPG). •Below -25°F (-32°C) - Refer to local supplier for ex- treme cold weather lubricant requirements. Pressure Control Valve Adjustment 1. With the truck engine running, install a jumper wire across the “LUBE SW.” and “SOL.” terminals on the lube timer under the passenger seat. SYSTEM PRIMING The system must be full of grease and free of air pockets to function properly. After maintenance, if the primary or secondary lubrication lines were replaced, it will be necessary to reprime the system to eject all entrapped air. 2. Loosen the locknut on the pressure control (1, Figure 3-5) by turning the nut counterclockwise. 3.
Turn the valve stem counterclockwise until it no longer turns. (The valve stem will unscrew until it reaches the stop - it will not come off.) 1. Fill lube reservoir with lubricant, if necessary. 2. To purge air from the main supply line, remove the main supply line at the pump outlet port (6, Figure 3-5) and connect an external grease supply to the line. Note: This is the minimum pressure setting, which is about 170 psi (1 172 kPa). 4. With the pump stalled against pressure, turn the pressure control valve stem clockwise until 325 to 350 psi (2 240 to 2 413 kPa) is attained on the manifold pressure gauge (3). 3.
Remove plugs from each injector group in sequence (right front, left front, and rear axle). 4. Using the external grease source, pump grease until grease appears at the group of injectors and re-install the pipe plug. Repeat for remaining injec- tor groups. 5. Tighten the locknut to lock the stem in position. Note: The flow control valve (5) is factory adjusted to 2.5 GPM (9.5 L/min.). Do not change this setting. 5. Remove the caps from each injector and connect an external grease supply to the zerk on the injector and pump until grease appears at the far end of the individual grease hose or the joint being greased.
LUBRICANT PUMP Pump Housing Oil Level The pump housing must be filled to the proper level with SAE 10W-30 motor oil. Oil level should be checked at 1000 hour intervals. To add oil, remove pipe plug (4, Figure 3-5) and fill housing to bottom of plug hole. FIGURE 3-5. PUMP CONTROLS 1. Pump Pressure Control 2. Manifold 3. Pressure Gauge 4. Oil Level Plug 5. Flow Control Valve 6. Outlet Port 7. Manual Override