Komatsu — EVERY 250 HOURS MAINTENANCE

. MAINTENANCE MAINTENANCE PROCEDURE CHECK AIR CONDITIONER COMPRESSOR BELT TENSION, ADJUST Adjustment 1. Open engine hood. 2. Remove guard (1). 3. Loosen bolts (2) and (3), then move compressor (4) to adjust. REMARK When the bolts (2) and (3) are loosened, compressor (4) can move, using the mounting position of bolt (2) as a fulcrum. 4. When the position of the compressor is determined, tighten bolts (2) and (3) to hold it in position.

4 - 50 When it is Possible to Use Indicator to Check Electrolyte Level If it is possible to u se an indicator to check the electro lyte leve l, follow the instructions give Checking Press the belt at a point midway between t he drive pu lley (B) and compressor pulley (A) with a finger force o f approx. 6 0 N (6.1 kg) (C) and check that the deflection is 6 to 9 mm (0.20 in to 0.40 in). NOTICE Check each pulley for damage, wear of the V- groove, and wear of th e V-belt. In particular, be sure to check that the V-belt is no touching the bott om of the V-groove. following occurs, ask the Komatsu distributor in your territory to replace the belts with new ones.

elongated, leaving little allowance for adjustment. s found on the belt. king sound is heard coming from the belt. elt is set, readjust it after one hour of operation. In case any of the following occurs, ask the Komatsu dist ributor in your territory to replace the bel • The fan belt has • A cut or crack i • Slipping or crea elongated, leaving little al lowance for adjustme king sound is heard comin g from the b When the new V-b elt is set, readjust it after o ne hour of o peration.