DRESSTA TD20H98/1E — 4.6.1. ETHER INJECTOR START

SECTION 4 OPERATING Page 18 4.6. STARTING THE ENGINE WARNING! Be sure all personnel are clear of the machine before starting the engine. Sound the horn. WARNING! Make sure the operator’s seat is adjusted properly and fasten the safety seat belt. NORMAL START (temperature above 0°C) 1. Apply and lock the brake and decelerator pedal. 2. Place transmission shift levers in neutral. 3. Place the neutral lock lever in vertical “ON” position. 4. Move the engine speed control lever to low speed (idle) position (Fig. 4.15). 5. Turn on electrical system master switch “ON”. Fig. 4.15. Engine Speed and Shut Down Control Lever 1. Sound the horn to clear all personnel from the immediate area. 2.

Crank engine. IMPORTANT: Crank engine for 30 seconds at a time. If engine does not start, allow cranking motor to cool two or three minutes before cranking again. 3. Check oil pressure. Stop the engine immediately if gauge fails to show correct pressure after 15 seconds. Allow the engine to idle for 3 to 5 minutes (app.1000 RPM.) before increasing the engine speed and placing under load. 4. Check indications of all instruments to ensure that machine is operating correctly. Refer to INSTRUMENT PANEL. IMPORTANT: It is not recommended to run the engine at low idle over 10 minutes due to possibility of faster wear of engine components. 4.6.1.

ETHER INJECTOR START (temperatures below 0°C) WARNING! Ether starting fluid is highly flammable. Follow the precautions on the container. An explosion can result if sparks or flame contact the ether or when storing ether container when the air temperature is above 70°C. TD-20H DRESSTA