DRESSTA TD20H98/1E — 4.6.2. ENGINE START AFTER OIL CHANGE OR PROLONGED STANDSTILL

OPERATING SECTION 4 Page 19 4.6. STARTING THE ENGINE Observe the following precautions: – Do not use the ether injector when the air temperature is above 0°C. – Do not use open flame when using ether starting fluid. – Do not store fluid containers in the operator's compartment. – Store the containers in a cool, well ventilated place. Keep the fluid containers out reach of children. – Do not breathe the hazardous ether vapor. – Do not let ether contact you skin, because it can cause frostbite.

– Never puncture the fluid container or put it into a fire – Dispose of empty containers per instructions printed on the container – For your safety, remove the ether container when welding, grinding, or using a torch on the machine. – Follow the correct method for starting the engine. – Before any attempt to start the engine, check the ether container or insure that a supply of starting fluid is available under pressure and the system is in working condition. Pressing the switch in the instrument panel makes ether injection. WARNING! Ether injector is to used only for starting. Misuse of ether injector while engine is running can result in serious damage to engine. 1.

Perform all activities as described in item 1-6. Refer to NORMAL START (temperature above 0°C). 2. Press engine button and ether injector switch simultaneously. Allow one to two seconds for chamber in valve to fill then, with engine cranking, release ether injector switch to release a measured shot of starting fluid into the engine. If temperature is below –18°C, additional ether may be required. If engine does not fire with a maximum of 4 injections, determine cause and correct before again attempting a start. IMPORTANT: Crank engine for 30 seconds at a time. If engine does not start, allow cranking motor to cool two or three minutes before cranking again. 4.6.2.

ENGINE START AFTER OIL CHANGE OR PROLONGED STANDSTILL (over 5 days) 1. Perform all activities as described in item 1 to 3 and 5 to 6. Refer to NORMAL START. 2. Place engine speed control lever in OFF position (Fig. 4.15). 3. Turn on engine start switch in the instrument panel. Crank the engine until oil gauge registers oil pressure or low oil pressure warning light goes off. 4. Depress the start switch. 5. Move the engine speed control lever to idle position. 6. Crank engine. 7. Perform all activities as described in item 8 to 9. Refer to NORMAL START. DRESSTA TD-20H