DRESSTA TD20H98/1E — 4.17.7. BULLDOZER BLADE POSITIONS

SECTION 4 OPERATING Page 28 4.17. OPERATING MOUNTED EQUIPMENT The control lever will return automatically to HOLD position when released (from “I” to “V” position) 2. Ripper Raise To raise the ripper to required height move the lever in “III” position. The control lever will return automatically to HOLD position “V” when released. 3. Ripper Lower To lower the ripper moves the lever in “IV” position. The control lever will return automatically to HOLD position “V” when released. NOTE: Holding the control lever in any position except HOLD for an extended period of time will produce excessive heat in the hydraulic system which may affect equipment performance. 4.17.7.

BULLDOZER BLADE POSITIONS TILTING THE BLADE (MECHANICAL TILT, FIG. 4.26) 1. Raise the blade 400 mm above the ground and shut off the engine. Refer to STOPPING THE ENGINE. 2. Remove the locking pin and adjust upper strut on the side to be raised. Extend the strut by the value equal approximately to half of required blade tilt. IMPORTANT: Do not expose any portion of the eyebolt threads. 3. Adjust the opposite side to get the desired tilt by shortening the strut by value equal to remaining part of desired tilt. Install locking pin. Fig. 4.26. Blade tilt 1 - Tilt to the Right 2 - Tilt to the Left IMPORTANT: Do not tilt the blade more than 560 mm tip to tip.

TILTING THE BLADE WITH HYDRAULIC TILT 1. To obtain a desired tilt of 400 mm or less, proceed as follows: a) Raise the blade about 450 mm off the ground. b) Hold the tilt control lever in the tilt position on the side to which the blade is to be tilted until the desired tilt is obtained. 2. To obtain a tilt of 400 mm to maximum 710 mm, proceed as follows: TD-20H DRESSTA