OPERATIONAL PERFORMANCE TEST / Adjustment LIFT ARM ANGLE SENSOR LEARNING (OPTIONAL) After removing and/or replacing the components as described below for repair, perform the left arm angle learning (calibration). Removal and installation of angle sensor, Replacement of angle sensor Replacement or repair of MC (Main Controller) Preparation: 1. Install Dr. ZX and start the engine. Select Boom Anlge and Angle Sensor Learning Status on the main controller screen in Dr. ZX. 2. Raise the lift arm to the highest position. At this time, check if voltage at Boom Angle on the display in Dr. ZX is 3.78±0.5 V. 3. If voltage 3.78±0.5 V is not displayed, the followings may be caused. Conduct the remedy.
The rotation shaft in angle sensor (1) turns with sensor lever (2) together. Angle sensor (1) failure 4. Set control lever lock (3) to LOCK position and stop the engine. 1 2 T4GB-04-06-008 3 LOCK M4GB-01-050 T4-6-6