OPERATIONAL PERFORMANCE TEST / Adjustment 5. Install calibration switch (5) to connector (4) (6-pole, gray) in relay box in 10 seconds after turning the key switch OFF (the battery relay is tuned OFF). At this time, return calibration start switch (6) to neutral. IMPORTANT: If the battery relay is not turned OFF, calibration cannot be performed. It takes 10 seconds to turn the battery relay OFF after turning the key switch OFF. 6. Lay down calibration start switch (6) to the lift arm side. Start the engine at idling speed. 7. If “Finish” in Angle Sensor Learning Status on Dr. ZX is turned into black, learning finishes. Return calibration start switch (6) to OFF (neutral).
If “Failed” or “Not Learn” in Angle Sensor Learning Status on Dr. ZX is turned into black, repeat the procedures from step 1. 8. Return the control lever lock to UNLOCK. Lower the lift arm onto the ground. Stop the engine. 9. After learning of the lift arm angle sensor, set the stop position of lift arm. (Refer to the Operator’s Manual.) Relay Box 4 T4GB-04-06-007 T4GB-04-06-001 5 6 T/M Lift Arm T4GB-04-06-003 T4-6-7