TROUBLESHOOTING / Diagnosing Procedure 5. Perform troubleshooting CAUTION: Do not disconnect harnesses or hydraulic lines while the engine is running. The machine may malfunction or pressurized oil may spout, possibly resulting in personal injury. Stop the engine before disconnecting harnesses or hydraulic lines. Perform diagnosis by connecting Dr. ZX to the machine or by using the service mode of monitor. In case any fault code has been displayed by di- agnosis by using Dr. ZX or the service mode of monitor, check the cause of the trouble by refer- ring to Troubleshooting A in this section. In case any fault code has been displayed by diagnosis by using Dr.
ZX or the service mode of monitor, write the fault code. Delete the fault code once and retry self-diagnosis again. If the fault code is displayed again, check the cause of the trouble by referring to Troubleshooting A in this section. After the machine trouble has been corrected, the fault code (displayed by the service mode of monitor) will be deleted. Therefore, in case prob- lems which are not easily re-predicable are en- countered (this states are repeated that the trouble is resolved later altough the troubole sometimes occurs), check the fault code by using Dr. ZX. T4GB-05-01-004 NOTE:
As for teach controller, the fault code and date when the trouble occurred, which are recorded by ICF, are effective in order to resolve the problem which are not easily re-predicable. (Refer to e-Wheel in this section.) In case the fault code is not displayed, check operating condition of each component by refer- ring to Troubleshooting B in this section and by using Dr.ZX or the service mode of monitor. T4GB-05-01-005 T4GB-05-01-006 T5-1-4