hitachi — MC Fault Code 11105

TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11105 Disconnect connector MC-C in MC. Check for continuity between terminal #C16 of harness end of connector and terminal #2 of harness end of connector in torque converter input shaft sensor. Open circuit in hranees between MC and torque converter input shaft sensor (terminal #2). NO YES NO Check if voltage between terminals #1 of harness end of connector in torque converter input shaft sensor and vehicle frame is 5 ± 0.5 V. Replace torque converter input shaft sensor. Start engine in 10 seconds after key switch is turned OFF. Travel machine 20 m. Retry. Check if fault code disappears. Disconnect connector MC-C in MC.

Check for continuity between terminal #C5 of harness end of connector and terminal #1 of harness end of connector in torque converter input shaft sensor. · Key switch: ON NO Open circuit in hranees between MC and torque converter input shaft sensor (terminal #1). NO · Key switch: ON Faulty MC and torque converter input shaft sensor. YES Connector (Harness end of connector viewed from the open end side) MC Connector MC-C #C5 C1 C10 C23 C31 #C16 Torque Converter Input Shaft Sensor Connector #1 #2 T5-5-76 Fault Code Trouble Cause Influenced Control 11105-3 Abnormal Torque Converter Input Shaft Sensor Engine speed=0 min-1 ECM engine speed>500 min-1 • Hydraulic rive Fan Cooling Control Faulty MC.

YES YES Faulty MC.