hitachi — Pump FailureMC Fault Code 11204

TROUBLESHOOTING / Troubleshooting A PUMP FAILURE MC FAULT CODE 11204 Fault Code Influenced Control 11204-3 Pump Torque Decrease Control: Disabled 11204-4 Pump Torque Decrease Control: Disabled Disconnect connector MC-C in MC. Check for continuity between terminal #C2 of harness end of connector and terminal #2 of harness end of connector in pump delivery pressure sensor. NO Open circuit in harnees between MC and pump delivery pressure sensor. YES Disconnect connector of pump delivery pressure sensor. Check if voltage between terminals #1 and #3 of harness end of connector is 5 ± 0.5 V.

NO Check if voltage between terminal #1 of harness end of connector in pump delivery pressure sensor and vehicle frame is specification. · Key switch: ON · Specification: 5 ± 0.5 V. YES Open circuit in harness between MC and pump delivery pressure sensor (terminal #3). Switch pump delivery pressure sensor with normal pressure sensor and retry. Check if fault code disappears. · Key switch: ON. NO Open circuit in harness between MC and pump delivery pressure sensor (terminal #1). NO Faulty pump delivery pressure sensor.

YES Connector (Harness end of connector viewed from the open end side) MC Connector MC-C Pump Delivery Pressure Sensor #C2 C1 C10 1 2 3 C23 C31 T5-5-77 Trouble Cause Abnormal Pump Delivery Pressure Sensor High Voltage Output voltage: 4.75 V or higher Abnormal Pump Delivery Pressure Sensor Low Voltage Output voltage: Less than 0.25 V Faulty MC. YES