TROUBLESHOOTING / Troubleshooting B T5-6-5 Evaluation by Fault Code Evaluation by Monitor Function NOTE Descriptions of Control (Operational Principle Section in T/M) MC: 11905 MC Monitor Item: Implement FNR switch, Selected speed gear, Actual speed gear, Backward alarm, Neutral signal • Although the forward/reverse lever is operated and the forward/reverse switch operation is disabled during the work, this contition is normal. T2-1 - MC Monitor Item: Implement FNR selector switch, Implement FNR mode, Implement FNR operating light • Although the forward/reverse lever is operated and the command signal from forward/reverse selector switch is disabled during the work, this contition is normal.
T2-1 - MC Monitor Item: Fan re- versing switch • If the switch is turned ON under the certaion conditions, the fan reversing control cannot be operated. • If the key switch is turned OFF and the fan reversing switch is turned OFF, turn the key ON in 10 seconds. If not, the fan reversing control is operated on the logic in MC. When the switches cprresponding to travel are operated, engine speed is fixed to the idling speed. This condition is normal. T2-1, T2-3 - MC Monitor Item: Ride con- trol switch • If the travel speed sensor is faulty, ride control is disabled. T2-1, T2-3 - Monitor Unit Monitor Item:
Emergency steering opera- tion check switch • When the engine starts, the emergency steering pump unit is operated for 2 seconds. This condition is normal. T2-1, T2-4 - MC Monitor Item: Boom height kickout switch, Boom height kickout setup switch, Ground stop switch, Ground stop setup switch • The lift arm auto leveler upward set switch and lift arm auto leveler downward set switch are installed. • Each lift arm auto leveler set switch consists of the auto leveler ON/OFF switch and lift arm stop position setup switch. • The lift arm stop position cannot be set without learning the angle sensor. (Refer to T4-6.) T2-1