TROUBLESHOOTING / Troubleshooting B F-11 Lift arm auto leveler is not operated. (Op- tional) Check the wiring connections first. Raise and lower lift arm. Check arm angle sensor shaft rotates according to link. · Put the matching mark on lift and shaft by using a white pen. Operate the lift arm several times in order to check. · Rotate the shaft where boom angle of MC monitor item by using Dr. ZX is 3.78 ± 0.5 V with lift arm at the highest position. Then, tighten link bolt.
Connector (Harness end of connector viewed from the open end side) Lift Arm Auto Leveler Switch Connector MC Connector B Lift Arm Angle Sensor Connector MC Connector D Lift Arm Solenoid Valve Connector #2 #B3 #1 #2 #3 #2 #1 T183-05-04-021 #B20 #10 T183-05-04-009 T5-6-54 YES To A Check if boom angle of MC monitor item by YES using Dr. ZX is 3.78±0.5 V with lift arm at highest position. Check if success is To B displayed on angle NO YES sensor learning status of MC monitor item by using Dr. ZX. · Engine: Running · Lift arm auto leveler switch: ON (2 used) Execute lift arm angle NO sensor learning. · Refer to the Operation Performance Test Tighten link bolt. NO Tighten link bolt.
NO 1 2 3 4 1 2 3 1 2