hitachi — Malfunction of Working Light Indicator

TROUBLESHOOTING / Troubleshooting C MALFUNCTION OF WORKING LIGHT IN- DICATOR Check if the working light switch and head light switch are in the ON position. If the clearance light indicator also does not light, the common circuit for clearance light indicator and working light indicator may be faulty. Refer to the Malfunction of Clearance Light Indicator sec- tion. Check the wiring connections first. Disconnect connector 1-B in monitor unit. Check if voltage at termi- nal #23 of harness end connector is 24 V. YES Faulty working light indicator. Open circuit in harness be- tween working light relay 1 (AR8) and monitor unit.

Although working light switch is turned to ON position, working light indicator does not light. NO Check if working light lights. Open circuit in harness be- tween fuse and working light relay 1 (AR8) or open circuit in fuse. Check if voltage at termi- nal #3 of working light re- lay 1 (AR8) is 24 V. NO NO Replace working light relay 1 (AR8) with working light relay 2 (AR7). Check if indicator lights. YES Replace working light relay 1 (AR8) with working light relay 2 (AR7). Check if indicator goes out. YES Faulty working light relay 1 (AR8). NO Although working light switch is turned to OFF position, working light indicator lights. Check if working light lights.

Shorted circuit in harness between working light relay 1 (AR8) and monitor unit. NO T5-7-16 YES YES r