Page 5 - 8 Section 5 – Maintenance Procedures CFP83 Series NOTE: If more than 59 ml (2 oz) is drained, refilling of the filter is required to prevent hard starting. Use your hand to open the drain valve. Turn the valve counterclockwise approximately 3Ѕ turns until the valve drops down 25.4 mm [1 in] and draining occurs. Drain the filter sump until clear fuel is visible. CAUTION When closing the drain valve, do not over-tighten the valve. Over-tightening can damage the threads. Close the valve by lifting the valve and turning it clockwise until it is hand-tight. If required, refill the filter. Refer to Change Fuel Filter later in this Section for removal and installation instructions.
Canister Type Shut off the engine. Pull up on the drain valve lever until fluid drains out of the drain tube. Drain the filter sump until clear fuel is visible. Push up on the drain valve until fluid drains out of the drain tube. Procedure 6b Inspect Charge Air Cooler Piping (CFP83-F40) Inspect the charge air cooler piping and hoses daily for holes, cracks, or loose connections. Tighten the hose clamps, if necessary. Torque Value: 8 N•m [72 in-lb] Drawing No. 9777, Section 5, Rev. 02-07