Section 5 – Maintenance Procedures Page 5 - 27 CFP83 Series Every Six Months or 500 Hours General Information All checks or inspections listed under daily or previous maintenance intervals must also be performed at this time, in addition to those listed under this maintenance interval. Procedure 27 Drain and Flush Cooling System The cooling system must be clean to work correctly. Drain the system and flush with clean water. If the system shows mineral buildup, scale, rust or oil, clean with a heavy duty engine coolant cleaner and follow the manufacturer’s directions. Drain CAUTION Avoid prolonged and repeated skin contact with used antifreeze.

Such prolonged, repeated contact can cause skin disorders or other bodily injury. CAUTION Wait until the temperature is below 50°C [120°F] before removing the coolant system pressure cap (Cummins Fire Power Part No. 11407). Failure to do so can cause personal injury from heated coolant spray. Avoid excessive contact - wash thoroughly after contact. Keep out of reach of children. Protect the environment : Handling and disposing of used antifreeze can be subject to federal, state, and local laws and regulations. Use authorized waste disposal facilities, including civic amenity sites and garages providing authorized facilities for the receipt of used antifreeze.

If in doubt, contact local authorities or the EPA for guidance as to proper handling of used antifreeze. Drawing No. 9777, Section 5, Rev. 02-07