Page 7-18 Section 7 – Adjustment, Repair, and Replacement CFP83 Series Coolant Heat Exchanger Removal/Installation (Cont) Remove the raw water inlet piping from the charge air cooler to the heat exchanger. (Refer to Drawing 10712 in Section 13 for raw water supply piping details.) CFP83-F40 Only Also, remove any customer-supplied raw water outlet fittings. Save these components for reuse. Pressure Test NOTE : This test is required if internal leakage in the heat exchanger is suspected. It may be performed prior to the removal from the engine. NOTE : Use teflon tape or other pipe sealant when installing the test setup in order to prevent leaks.
Install a 1-1/4” NPT pipe plug at the raw water outlet of the heat exchanger. Install a pressure test setup with 700 kPa [100 psi] pressure gauge at the 1” NPT raw water inlet to the heat exchanger. NOTE : There should be no detectable decrease in the pressure reading for the duration of the test. Apply air pressure at 621 kPa [90 psig]. Isolate the pressure source and monitor the pressure gauge for 5 minutes. After testing, release the pressure. Remove the pipe plug and the test setup. If leakage is detected, the heat exchanger must be replaced. Drawing No. 9777, Section 7, Rev. 02-07