Page 7-44 Section 7 – Adjustment, Repair, and Replacement CFP83 Series Raw Water Solenoid Valve Removal/Installation (Cont) Follow-Up WARNING Batteries can emit explosive gases. To reduce the possibility of personal injury, always ventilate the compartment before servicing the batteries. To reduce the possibility of arcing, remove the negative (-) battery cable first and attach the negative (-) battery cable last. Connect the positive battery cables at both batteries. Open the Raw Water Manifold Normal Line Inlet Isolation Valve. Open the Raw Water Manifold Normal Line Outlet Isolation Valve. Place the AUTO/MANUAL Switch at the local panel in the MANUAL position. Operate the engine.
Refer to Operating Instructions in Section 3. Check for leaks. Repair any leaks. Check that raw water flow starts when the engine starts. Stop the engine. Check that raw water flow stops shortly after the engine stops. If raw water flow does not start when the engine starts, refer to Coolant Temperature Above Normal in Troubleshooting Section 12. If raw water flow does not stop shortly after the engine stops, refer to Troubleshooting Section 12. Drawing No. 9777, Section 7, Rev. 02-07